Cylindrical Mould Calibration — Global Lab India
NABL Accredited · Equipment Calibration

Cylindrical Mould Calibration(IS 10086 — Dimensional Verification)

Dimensional calibration of concrete cylinder moulds — internal diameter, height, planeness and rigidity verified against IS 10086 tolerances with NPLI-traceable dimensional standards.

IS 10086
Mould Tolerances
2–4 Days
Report TAT
NABL
Accredited
NABL Accredited Lab · ISO/IEC 17025:2017
Digital Reports via Autovity QLMS
Pan-India · 7 Lab Locations
Est. 2009 · 20,000+ Projects

What is Cylindrical Mould Calibration?

Cylinder strength results are only as good as the mould that cast them: an out-of-round or under-height mould biases every specimen it produces. IS 10086:1982 (Specification for Moulds for Use in Tests of Cement and Concrete) fixes the internal dimensions, tolerances, planeness and rigidity requirements for cylindrical moulds used in compressive and split-tensile testing.

Global Lab calibrates moulds with traceable internal micrometers, depth gauges and straightedges — verifying internal diameter at multiple orientations and heights, overall height, base-plate planeness and wall thickness — and certifies each mould against the IS 10086 tolerance band with as-found readings.

Reviewed by Mahemood Ahmad, Lab Manager — NABL Accredited Laboratory, Global Lab India
NPLI-Traceable References
Reference standards with unbroken traceability to national standards.
ISO/IEC 17025 System
Calibration under our accredited laboratory quality system.
All Critical Dimensions
Diameter (multi-orientation), height, planeness, wall condition.
Fast Turnaround
Certificates in 2–4 days — minimal instrument downtime.
As-Found / As-Left Data
Both states recorded, so drift since last calibration is visible.
Digital Certificates
Calibration certificates via the Autovity QLMS dashboard.

How the Cylindrical Mould Calibration is Conducted

  • 1

    Identification & Condition Check

    Mould ID, size class and physical condition (dents, weld cracks, seized clamps) are recorded before measurement.
  • 2

    Internal Diameter Measurement

    Diameter is measured with a traceable internal micrometer at multiple heights and orientations to capture ovality.
  • 3

    Height & Planeness

    Height is gauged at several positions; base-plate planeness is checked with straightedge and feeler gauges.
  • 4

    Tolerance Evaluation

    All readings are evaluated against the IS 10086 tolerance band for the mould class.
  • 5

    Certification

    As-found data, verdict and next-due date are issued via Autovity QLMS.

Applicable Test Standards

StandardTitleScopeType
IS 10086:1982Specification for Moulds for Use in Tests of Cement and Concrete (Reaffirmed)Dimensional TolerancesIndian Standard
IS 516 (Pt 1/Sec 1):2021Hardened Concrete — Compressive Strength — Testing of Moulded SpecimensSpecimen RequirementsIndian Standard
ISO/IEC 17025:2017General Requirements for the Competence of Testing and Calibration LaboratoriesCalibration SystemInternational

Where is the Cylindrical Mould Calibration Used?

Concrete testing lab mould fleets (NABL scope compliance)
RMC plant QC mould verification
Site laboratory audit preparation
Cylinder moulds for core-correlation programmes
Periodic recalibration under lab quality systems
Pre-purchase acceptance of new moulds

Our Advantages

Audit-Ready CertificatesFormats aligned to NABL assessment and customer audit expectations.
Measured Uncertainty StatedEvery certificate reports measurement uncertainty, not just readings.
Drift VisibilityAs-found/as-left records expose instruments drifting out of tolerance.
Lab + On-Site OptionsSite calibration available for fixed or heavy equipment.
Reminder TrackingDue-date tracking so recalibration is never missed.
Digital ReportingCertificates delivered via the Autovity QLMS dashboard.

Frequently Asked Questions

What standard governs the Cylindrical Mould Calibration?
Cylindrical Mould Calibration is tested per IS 10086:1982, IS 516 (Pt 1/Sec 1):2021 and ISO/IEC 17025:2017.
How long does the Cylindrical Mould Calibration take?
Reports are typically issued within 2–4 Days of sample receipt at the lab, delivered digitally via the Autovity QLMS client dashboard.
Where is the Cylindrical Mould Calibration used?
It is commonly used for concrete testing lab mould fleets (NABL scope compliance), and for RMC plant QC mould verification.
Get Started Today
Ready to request the Cylindrical Mould Calibration?
Schedule a site visit or send samples — our team responds within 2 hours.