Skip links
Pressure Gauge Calibration — Global Lab India
NABL Accredited · Equipment Calibration

Pressure Gauge Calibration(DKD-R 6-1 Practice · IS 3624)

Calibration of pressure and vacuum gauges against dead-weight testers and master gauges — ascending/descending points across the range per DKD-R 6-1 practice, with IS 3624 accuracy-class verdicts.

DWT
Dead-Weight Traceable
2–4 Days
Report TAT
NABL
Accredited
NABL Accredited Lab · ISO/IEC 17025:2017
Digital Reports via Autovity QLMS
Pan-India · 7 Lab Locations
Est. 2009 · 20,000+ Projects

What is Pressure Gauge Calibration?

Pressure gauges sit on everything from compression testing machines to autoclaves and triaxial panels — and their errors go straight into reported results. IS 3624 (Pressure and Vacuum Gauges — Specification) defines the accuracy classes; the widely-adopted DKD-R 6-1 guideline defines good calibration practice: preloading, ascending and descending measurement series, hysteresis evaluation and uncertainty statement.

Global Lab calibrates gauges against dead-weight testers and traceable master gauges, at multiple points covering the working range in both directions, reporting error, hysteresis and uncertainty with an accuracy-class verdict — lab or on-site for panel-mounted gauges.

Reviewed by Mahemood Ahmad, Lab Manager — NABL Accredited Laboratory, Global Lab India
NPLI-Traceable References
Reference standards with unbroken traceability to national standards.
ISO/IEC 17025 System
Calibration under our accredited laboratory quality system.
Both-Direction Series
Ascending + descending points with hysteresis evaluation.
Fast Turnaround
Certificates in 2–4 days — minimal instrument downtime.
As-Found / As-Left Data
Both states recorded, so drift since last calibration is visible.
Digital Certificates
Calibration certificates via the Autovity QLMS dashboard.

How the Pressure Gauge Calibration is Conducted

  • 1

    Identification & Zero Check

    Gauge details, range and class are recorded; zero indication and pointer condition checked.
  • 2

    Connection & Preload

    The gauge is connected to the dead-weight tester / master line and preloaded to full scale per practice.
  • 3

    Ascending Series

    Calibration points across the range are applied in ascending order and indications recorded.
  • 4

    Descending Series

    The same points are approached in descending order to quantify hysteresis.
  • 5

    Evaluation

    Errors are evaluated against the accuracy-class tolerance with computed uncertainty.
  • 6

    Certification

    As-found/as-left results are issued via Autovity QLMS.

Applicable Test Standards

StandardTitleScopeType
DKD-R 6-1Calibration of Pressure Gauges (Guideline)Calibration MethodInternational Guideline
IS 3624:1987Pressure and Vacuum Gauges — Specification (Reaffirmed)Accuracy ClassesIndian Standard
ISO/IEC 17025:2017Competence of Testing and Calibration LaboratoriesCalibration SystemInternational

Where is the Pressure Gauge Calibration Used?

CTM / UTM hydraulic gauge verification
Autoclave and curing equipment gauges
Triaxial and consolidation panel gauges
Industrial process and utility gauges
Batching plant hydraulic systems
Pre-audit calibration of lab gauge fleets

Our Advantages

Audit-Ready CertificatesFormats aligned to NABL assessment and customer audit expectations.
Measured Uncertainty StatedEvery certificate reports measurement uncertainty, not just readings.
Drift VisibilityAs-found/as-left records expose instruments drifting out of tolerance.
Lab + On-Site OptionsSite calibration available for fixed or heavy equipment.
Reminder TrackingDue-date tracking so recalibration is never missed.
Digital ReportingCertificates delivered via the Autovity QLMS dashboard.

Frequently Asked Questions

What standard governs the Pressure Gauge Calibration?
Pressure Gauge Calibration is tested per DKD-R 6-1, IS 3624:1987 and ISO/IEC 17025:2017.
How long does the Pressure Gauge Calibration take?
Reports are typically issued within 2–4 Days of sample receipt at the lab, delivered digitally via the Autovity QLMS client dashboard.
Where is the Pressure Gauge Calibration used?
It is commonly used for CTM / UTM hydraulic gauge verification, and for autoclave and curing equipment gauges.
Get Started Today
Ready to request the Pressure Gauge Calibration?
Schedule a site visit or send samples — our team responds within 2 hours.