NABL Accredited · Dimensional Calibration
Flow Table Calibration
(IS 10078 / IS 5512 — Cement Flow Table)
NABL-accredited calibration of flow tables per IS 10078 — verifying 12.5mm drop height, table diameter, levelness and cam mechanism for cement and SCC flow consistency testing.
IS 10078
Standard
±0.2mm
Accuracy
1 Day
Report TAT
NABL
Accredited
NABL Accredited Lab · ISO/IEC 17025:2017
Digital Reports via Autovity QLMS
Pan-India · 7 Lab Locations
Est. 2009 · 20,000+ Projects
Overview
What is the Flow Table Calibration?
The Flow Table measures consistency of cement paste, mortar and fresh concrete by dropping through 12.5mm height for 15 drops. Drop height (12.5±0.2mm) is the critical calibration parameter — incorrect height changes energy input and directly affects measured flow diameter.
At Global Lab, flow table calibration per IS 10078 verifies: table diameter (300mm ±1mm), levelness (spirit level), drop height (12.5±0.2mm by calibrated depth gauge), cam mechanism operation and table surface flatness.
Non-Destructive
Minimal surface preparation. Structure integrity is preserved throughout testing.
Fast Turnaround
On-site results within hours. Digital reports dispatched within 24 hours.
NABL Certified
All test and calibration results are backed by traceable measurements and standardized procedures.
Pan-India Coverage
Site engineers deployed across 7 lab locations and all major project sites.
Digital Reporting
Access reports anytime via Autovity QLMS client dashboard — zero paperwork.
High Accuracy
Results correlated to cube compressive strength with ±2% precision range.
Test in Action
Flow Table Calibration — Site Images
Drop Height 12.5mm Measured with Calibrated Depth Gauge
Table Levelness Check with Spirit Level
IS 10078 Certificate — Flow Table Dimensional Compliance
Test Procedure
How the Flow Table Calibration is Conducted
-
1
Surface Preparation
A shallow groove (approx. 25mm deep) is cut into the concrete surface using a diamond-tipped cutting tool. The surface is cleaned of dust and debris. -
2
Insert Disc Placement
A specially designed steel insert disc is placed into the groove. A thin rod connects the disc to the pullout apparatus above the surface. -
3
Hydraulic Pullout Force Application
A hydraulic jack applies a steady, controlled pullout force to the insert disc via the reaction ring resting on the concrete surface. -
4
Failure Load Recording
The maximum force at which the concrete cone is extracted is recorded. A digital load indicator provides real-time readings with data logging. -
5
Strength Calculation & Reporting
The pullout force is correlated to cube compressive strength using established calibration curves. NABL-accredited reports are issued via Autovity QLMS.
Standards & Specifications
Applicable Test Standards
| Standard | Title | Scope | Type |
|---|---|---|---|
| IS 10078 | Specification for Flow Table for Hydraulic Cement Tests | Flow Table | Indian Standard |
| IS 5512 | Specification for Flow Table for Cement and Lime Tests | Cement Flow Table | Indian Standard |
| IS 1199 | Methods of Sampling and Analysis of Concrete | Reference | Indian Standard |
| NABL-141 | NABL Policy on Metrological Traceability | Traceability | NABL |
Applications
Where is the Flow Table Calibration Used?
Annual flow table calibration for NABL cement laboratory
IS 4031 cement consistency flow table calibration
SCC slump flow test table calibration
Admixture dosage optimisation calibration
Pre-NABL assessment flow table calibration
Cement workability dispute investigation
Why Choose Global Lab
Our Advantages
NABL Accredited CertificatesIS 10078 certificates for NABL cement lab assessment.
Drop Height Critical12.5mm certified — most commonly wrong flow table parameter.
Levelness DocumentedTable levelness measured and documented.
Fast 1-Day CertificateCertificate within 1 working day.
Pan-India CoverageDimensional calibration at all 7 locations.
Cement Lab PackageFlow table + Vicat + Le-Chatelier + Gang in one visit.
Get Started Today
Ready to request the Flow Table Calibration?
Schedule a site visit or send samples — our team responds within 2 hours.