Elongation Gauge Calibration
(IS 2386 Part 1 — Aggregate Elongation Index)

NABL-accredited calibration of elongation gauges per IS 2386 Part 1 — verifying pin-to-pin spacing for each aggregate size fraction for accurate elongation index determination.

IS 2386 Pt.1
Standard
±0.1mm
Accuracy
1 Day
Report TAT
NABL
Accredited
NABL Accredited Lab · ISO/IEC 17025:2017
Digital Reports via Autovity QLMS
Pan-India · 7 Lab Locations
Est. 2009 · 20,000+ Projects

What is the Elongation Gauge Calibration?

The Elongation Gauge has pins set at specified spacings for each aggregate size fraction — separating elongated particles (length > 1.8× mean sieve size). IS 2386 Part 1 specifies pin spacing per fraction from Table 2. Out-of-dimension gauges produce systematic EI errors.

At Global Lab, elongation gauge calibration verifies pin-to-pin spacing using calibrated Vernier calipers and slip gauges — comparing against IS 2386 Part 1 Table 2. Each pin-to-pin spacing reported individually on the NABL certificate.

Non-Destructive

Minimal surface preparation. Structure integrity is preserved throughout testing.

Fast Turnaround

On-site results within hours. Digital reports dispatched within 24 hours.

NABL Certified

All test and calibration results are backed by traceable measurements and standardized procedures.

Pan-India Coverage

Site engineers deployed across 7 lab locations and all major project sites.

Digital Reporting

Access reports anytime via Autovity QLMS client dashboard — zero paperwork.

High Accuracy

Results correlated to cube compressive strength with ±2% precision range.

How the Elongation Gauge Calibration is Conducted

  • 1

    Surface Preparation

    A shallow groove (approx. 25mm deep) is cut into the concrete surface using a diamond-tipped cutting tool. The surface is cleaned of dust and debris.
  • 2

    Insert Disc Placement

    A specially designed steel insert disc is placed into the groove. A thin rod connects the disc to the pullout apparatus above the surface.
  • 3

    Hydraulic Pullout Force Application

    A hydraulic jack applies a steady, controlled pullout force to the insert disc via the reaction ring resting on the concrete surface.
  • 4

    Failure Load Recording

    The maximum force at which the concrete cone is extracted is recorded. A digital load indicator provides real-time readings with data logging.
  • 5

    Strength Calculation & Reporting

    The pullout force is correlated to cube compressive strength using established calibration curves. NABL-accredited reports are issued via Autovity QLMS.

Applicable Test Standards

Standard Title Scope Type
IS 2386 Part 1 Methods of Test for Aggregates — Particle Size and Shape Elongation Test Indian Standard
IS 2984 Gauge Blocks Reference Standard Indian Standard
IS 3651 Vernier Calipers Reference Instrument Indian Standard
NABL-141 NABL Policy on Metrological Traceability Traceability NABL

Where is the Elongation Gauge Calibration Used?

Annual elongation gauge calibration for NABL aggregate lab
NHAI MORTH road aggregate EI specification calibration
Quarry QA/QC elongation gauge calibration
Combined flakiness and elongation package
Pre-NABL assessment for aggregate scope
EI results dispute investigation

Our Advantages

NABL Accredited CertificatesIS 2386 Part 1 elongation gauge certificates for NABL assessment.
Every Pin PairEach size fraction individually measured and certified.
Combined FlakinessElongation + Flakiness in one visit — efficient.
Fast 1-Day CertificateCertificate within 1 working day.
Pan-India CoverageDimensional calibration at all 7 locations.
Aggregate PackageElongation + Flakiness + Sieve together.