Skip links
Hydraulic Cement Testing — Global Lab India
NABL Accredited · Building Material Testing

Hydraulic Cement Testing
(OPC, PPC, PSC — IS 269)

Complete physical and mechanical testing of ordinary Portland cement, Portland pozzolana cement and Portland slag cement as per IS 269 — verifying fineness, consistency, setting time, soundness and strength.

IS 269
Standard
±2%
Accuracy
35 Days
Report TAT
NABL
Accredited
NABL Accredited Lab · ISO/IEC 17025:2017
Digital Reports via Autovity QLMS
Pan-India · 7 Lab Locations
Est. 2009 · 20,000+ Projects

What is the Hydraulic Cement Testing?

Hydraulic Cement Testing verifies that cement supplied to a project meets the mandatory requirements of IS 269 (OPC), IS 1489 (PPC) or IS 455 (PSC). Physical tests include fineness, normal consistency, initial and final setting time, soundness (Le-Chatelier) and autoclave expansion. Strength tests cover 3, 7 and 28-day mortar cube compressive strength.

At Global Lab, cement testing is conducted in our NABL-accredited laboratory with calibrated Vicat apparatus, Le-Chatelier moulds, mortar cube moulds and compression testing machines. Cement quality directly governs concrete strength, durability and long-term performance — making incoming quality control testing essential for all projects.

Complete IS 269 Test Suite
All mandatory physical and mechanical tests per IS 269/1489/455.
Vicat Setting Time
Initial (≥30 min) and final (≤600 min) setting times per IS 4031 Part 5.
Soundness Testing
Le-Chatelier expansion (≤10mm) and autoclave expansion per IS 4031 Part 3.
28-Day Mortar Cube Strength
Definitive cement strength test — 3, 7 and 28-day results per IS 4031 Part 6.
NABL Certified Reports
All results on NABL-accredited letterhead with IS 269 compliance statement.
Fineness — Blaine & Sieve
Blaine specific surface area and 90μm/45μm sieve residue per IS 4031.

How the Hydraulic Cement Testing is Conducted

  • 1
    Sample Collection & Quartering
    Cement sample collected from truck/bag as per IS 3535. Sample quartered to test portions.
  • 2
    Fineness Testing
    Blaine air permeability method (IS 4031 Part 2) and dry sieve method (IS 4031 Part 1) conducted.
  • 3
    Consistency, Setting Time & Soundness
    Normal consistency (IS 4031 Part 4), Vicat setting time (Part 5), Le-Chatelier soundness (Part 3).
  • 4
    Mortar Cube Casting & Curing
    Standard mortar cubes (1:3 cement:sand, w/c=0.4) cast per IS 4031 Part 6. Cured at 27±2°C.
  • 5
    Strength Testing & Report
    Cubes tested at 3, 7 and 28 days. Results vs IS 269 minimum strength requirements. NABL report within 35 days.

Applicable Test Standards

Standard Title Scope Type
IS 269 Ordinary Portland Cement — Specification OPC Testing Indian Standard
IS 1489 Portland Pozzolana Cement — Specification PPC Testing Indian Standard
IS 455 Portland Slag Cement — Specification PSC Testing Indian Standard
IS 4031 Methods of Physical Tests for Hydraulic Cement (Parts 1–15) Cement Testing Indian Standard

Where is the CAPO Test Used?

Incoming quality control of cement at construction sites and RMC plants
Approval of new cement brands for use on government and infrastructure projects
Batch acceptance testing for cement stored on site for extended periods
Third-party verification testing for cement procurement disputes
Research on cement quality variation between manufacturing batches
Pre-qualification of cement suppliers for large infrastructure contracts

Our Advantages

NABL Accredited ReportsLegally valid IS 269 compliance certificates for all procurement requirements.
Complete 35-Day Test PackageAll physical and mechanical tests from fineness to 28-day strength.
Autovity Digital ReportsAccess cement test results and strength development data digitally.
Experienced Cement Testing Lab15+ years of cement testing for infrastructure, precast and RMC industries.
Pan-India Sample CollectionSample collection from cement plants, sites and depots across India.
Multiple Cement TypesOPC 43, OPC 53, PPC, PSC, SRC, white cement and blended cements.
Get Started Today
Ready to request the Hydraulic Cement Testing?
Schedule a site visit or send samples — our team responds within 2 hours.