Proficiency Testing — Thermocouple (With & Without Indicator)(Interlaboratory Comparison — Temperature Sensors)
ISO/IEC 17043-aligned proficiency testing scheme for thermocouple (with and without indicator) calibration — circulated reference artefacts, ISO 13528 statistical evaluation (En / z-scores), and confidential performance reports for NABL-accredited and aspiring calibration laboratories.
What is the Proficiency Testing — Thermocouple (With & Without Indicator) Scheme?
Under ISO/IEC 17025:2017 (clause 7.7), every accredited calibration laboratory must monitor the validity of its results by participating in proficiency testing (PT) — and NABL expects documented, satisfactory PT participation across the accredited scope. Global Lab operates an ISO/IEC 17043:2023-aligned interlaboratory comparison scheme for thermocouple (with and without indicator) calibration: a characterised artefact travels between participating labs, each calibrates it by their normal method, and results are evaluated statistically against the assigned reference value.
Thermocouples dominate high-temperature calibration scopes — and their drift behaviour makes interlaboratory checks more revealing than any internal QC. The scheme measurand covers calibration of base/noble-metal thermocouples, bare and with indicators, by comparison, with results reported at agreed comparison temperatures including elevated-range points. Each participant receives a confidential performance report — En numbers and z-scores per ISO 13528 — through our Live PT Program portal, with anonymised group statistics and corrective-action guidance where performance flags arise.
How the Proficiency Testing — Thermocouple (With & Without Indicator) is Conducted
- 1
Enrolment
The laboratory enrols for the thermocouple (with and without indicator) scheme round through the Live PT Program portal and receives the scheme protocol. - 2
Artefact Receipt
The characterised artefact arrives per the circulation schedule with handling instructions and condition-check requirements. - 3
Calibration by Your Method
Your lab calibrates the circulated thermocouple by its normal comparison method against its reference chain and reports EMF/temperature values with uncertainties. - 4
Result Submission
Results with claimed uncertainties are submitted through the portal by the round deadline. - 5
Statistical Evaluation
Submissions are evaluated against the assigned value per ISO 13528 — En numbers and z-scores computed per measurement point. - 6
Performance Report
A confidential report with your performance flags and anonymised group statistics is issued; corrective-action guidance follows any unsatisfactory result.
Applicable Test Standards
| Standard | Title | Scope | Type |
|---|---|---|---|
| ISO/IEC 17043:2023 | Conformity Assessment — General Requirements for the Competence of Proficiency Testing Providers | PT Scheme Operation | International |
| ISO 13528:2022 | Statistical Methods for Use in Proficiency Testing by Interlaboratory Comparison | En / z-Score Evaluation | International |
| ISO/IEC 17025:2017 | Competence of Testing and Calibration Laboratories (Clause 7.7) | Participation Requirement | International |
| IEC 60584 | Thermocouples — EMF Specifications and Tolerances | Sensor Class Context | Method Standard |