Vicat Apparatus Calibration
(IS 5513 — Cement Consistency & Setting Time)

NABL-accredited calibration of Vicat apparatus per IS 5513 — verifying 10mm plunger diameter, 1.13mm needle diameter, 300g moving rod mass, scale accuracy and guide frame alignment for IS 4031 cement testing.

IS 5513
Standard
±0.5mm
Accuracy
1 Day
Report TAT
NABL
Accredited
NABL Accredited Lab · ISO/IEC 17025:2017
Digital Reports via Autovity QLMS
Pan-India · 7 Lab Locations
Est. 2009 · 20,000+ Projects

What is the Vicat Apparatus Calibration?

The Vicat Apparatus measures cement consistency (10mm plunger) and setting time (1mm needle) per IS 4031 Parts 4 and 5. IS 5513 specifies plunger diameter, needle diameter, moving rod mass (300±1g), scale graduation and reference zero. Out-of-specification components produce incorrect results.

At Global Lab, Vicat calibration per IS 5513 verifies: plunger diameter (10±0.05mm), Vicat needle diameter (1.13±0.05mm), moving rod + plunger mass (300±1g), scale reading vs actual penetration, and guide frame alignment.

Non-Destructive

Minimal surface preparation. Structure integrity is preserved throughout testing.

Fast Turnaround

On-site results within hours. Digital reports dispatched within 24 hours.

NABL Certified

All test and calibration results are backed by traceable measurements and standardized procedures.

Pan-India Coverage

Site engineers deployed across 7 lab locations and all major project sites.

Digital Reporting

Access reports anytime via Autovity QLMS client dashboard — zero paperwork.

High Accuracy

Results correlated to cube compressive strength with ±2% precision range.

How the Vicat Apparatus Calibration is Conducted

  • 1

    Surface Preparation

    A shallow groove (approx. 25mm deep) is cut into the concrete surface using a diamond-tipped cutting tool. The surface is cleaned of dust and debris.
  • 2

    Insert Disc Placement

    A specially designed steel insert disc is placed into the groove. A thin rod connects the disc to the pullout apparatus above the surface.
  • 3

    Hydraulic Pullout Force Application

    A hydraulic jack applies a steady, controlled pullout force to the insert disc via the reaction ring resting on the concrete surface.
  • 4

    Failure Load Recording

    The maximum force at which the concrete cone is extracted is recorded. A digital load indicator provides real-time readings with data logging.
  • 5

    Strength Calculation & Reporting

    The pullout force is correlated to cube compressive strength using established calibration curves. NABL-accredited reports are issued via Autovity QLMS.

Applicable Test Standards

Standard Title Scope Type
IS 5513 Specification for Vicat Apparatus Vicat Apparatus Indian Standard
IS 4031 Part 4 Physical Tests for Hydraulic Cement — Normal Consistency Consistency Test Indian Standard
IS 4031 Part 5 Physical Tests for Hydraulic Cement — Setting Time Setting Time Indian Standard
NABL-141 NABL Policy on Metrological Traceability Traceability NABL

Where is the Vicat Apparatus Calibration Used?

Annual Vicat calibration for NABL cement laboratory
IS 4031 Parts 4 and 5 consistency and setting time calibration
BIS-licensed cement manufacturer testing laboratory
RMC plant cement incoming QC Vicat calibration
Pre-NABL assessment for cement scope
Cement setting time dispute investigation

Our Advantages

NABL Accredited CertificatesIS 5513 Vicat certificates for NABL cement lab assessment.
Mass Calibration IncludedMoving rod mass verified — most critical and most commonly wrong.
Plunger & Needle BothNormal consistency and setting time components calibrated.
Fast 1-Day CertificateCertificate within 1 working day.
Pan-India CoverageDimensional calibration at all 7 locations.
Complete Cement PackageVicat + Gang + Le-Chatelier + Flow table in one visit.
Get Started Today
Ready to request the Vicat Apparatus Calibration?
Schedule a site visit or send samples — our team responds within 2 hours.