Skip links
Proficiency Testing — Accelerated Curing Tank — Global Lab India
ISO/IEC 17043 · Proficiency Testing

Proficiency Testing — Accelerated Curing Tank(Interlaboratory Comparison — IS 9013 Cycle Verification)

ISO/IEC 17043-aligned proficiency testing scheme for accelerated curing tank (cycle verification) calibration — circulated reference artefacts, ISO 13528 statistical evaluation (En / z-scores), and confidential performance reports for NABL-accredited and aspiring calibration laboratories.

|En|≤1
Satisfactory Criterion
Per Round
Report TAT
NABL
Accredited
NABL Accredited Lab · ISO/IEC 17025:2017
Digital Reports via Autovity QLMS
Pan-India · 7 Lab Locations
Est. 2009 · 20,000+ Projects

What is the Proficiency Testing — Accelerated Curing Tank Scheme?

Under ISO/IEC 17025:2017 (clause 7.7), every accredited calibration laboratory must monitor the validity of its results by participating in proficiency testing (PT) — and NABL expects documented, satisfactory PT participation across the accredited scope. Global Lab operates an ISO/IEC 17043:2023-aligned interlaboratory comparison scheme for accelerated curing tank (cycle verification) calibration: a characterised artefact travels between participating labs, each calibrates it by their normal method, and results are evaluated statistically against the assigned reference value.

Accelerated-strength correlations collapse if the 55°C/boiling cycle drifts — cycle-verification PT keeps prediction programmes credible across labs. The scheme measurand covers verification of accelerated curing cycle temperatures and durations per IS 9013, with results reported at the method cycle profile positions. Each participant receives a confidential performance report — En numbers and z-scores per ISO 13528 — through our Live PT Program portal, with anonymised group statistics and corrective-action guidance where performance flags arise.

Reviewed by Mahemood Ahmad, Lab Manager — NABL Accredited Laboratory, Global Lab India
ISO/IEC 17043-Aligned
Scheme design, artefact handling and reporting per the PT provider standard.
ISO 13528 Statistics
En numbers and z-scores computed by the recognised statistical methods.
NABL Clause 7.7 Evidence
Participation certificates and performance reports ready for assessment files.
Scheduled Rounds
Published round calendar — plan participation across your scope.
Stable Reference Artefacts
Characterised, stability-monitored artefacts with assigned values.
Live PT Portal
Result submission and confidential reports via the Live PT Program.

How the Proficiency Testing — Accelerated Curing Tank is Conducted

  • 1

    Enrolment

    The laboratory enrols for the accelerated curing tank (cycle verification) scheme round through the Live PT Program portal and receives the scheme protocol.
  • 2

    Artefact Receipt

    The characterised artefact arrives per the circulation schedule with handling instructions and condition-check requirements.
  • 3

    Calibration by Your Method

    Your lab verifies the designated tank through a full method cycle by its normal procedure and reports the temperature-time profile with uncertainties.
  • 4

    Result Submission

    Results with claimed uncertainties are submitted through the portal by the round deadline.
  • 5

    Statistical Evaluation

    Submissions are evaluated against the assigned value per ISO 13528 — En numbers and z-scores computed per measurement point.
  • 6

    Performance Report

    A confidential report with your performance flags and anonymised group statistics is issued; corrective-action guidance follows any unsatisfactory result.

Applicable Test Standards

StandardTitleScopeType
ISO/IEC 17043:2023Conformity Assessment — General Requirements for the Competence of Proficiency Testing ProvidersPT Scheme OperationInternational
ISO 13528:2022Statistical Methods for Use in Proficiency Testing by Interlaboratory ComparisonEn / z-Score EvaluationInternational
ISO/IEC 17025:2017Competence of Testing and Calibration Laboratories (Clause 7.7)Participation RequirementInternational
IS 9013:1978Accelerated-Cured Concrete Test Specimens (Reaffirmed)Method Cycle ContextIndian Standard

Where is the Proficiency Testing — Accelerated Curing Tank Used?

NABL-accredited calibration labs — clause 7.7 compliance for accelerated curing tank (cycle verification) scope
Labs preparing NABL applications needing pre-assessment PT evidence
Method validation cross-checks after procedure changes
New technician competence demonstration
Inter-branch consistency checks in multi-site laboratories
Corrective-action effectiveness verification after prior flags

Our Advantages

Indian Scheme, Indian LogisticsArtefact circulation designed for Indian lab geography — no import delays.
Confidential ReportingYour identity is coded; only your lab sees its own performance.
Assessment-Ready EvidenceReports formatted for NABL assessor expectations.
Corrective-Action SupportFlagged results come with guidance, not just a score.
Portal-Based WorkflowEnrolment to report — fully digital via Live PT Program.
Round Calendar DisciplineScheduled rounds let you plan scope-wide participation.

Frequently Asked Questions

What standard governs the PT — Accelerated Curing Tank?
PT — Accelerated Curing Tank is tested per ISO/IEC 17043:2023, ISO 13528:2022 and ISO/IEC 17025:2017.
How long does the PT — Accelerated Curing Tank take?
Reports are typically issued within Per Round of sample receipt at the lab, delivered digitally via the Autovity QLMS client dashboard.
Where is the PT — Accelerated Curing Tank used?
It is commonly used for NABL-accredited calibration labs — clause 7.7 compliance for accelerated curing tank (cycle verification) scope, and for labs preparing NABL applications needing pre-assessment PT evidence.
Get Started Today
Ready to request the Proficiency Testing — Accelerated Curing Tank?
Schedule a site visit or send samples — our team responds within 2 hours.