GGBS Testing
(Ground Granulated Blast Furnace Slag — IS 16714)

Complete physical and chemical testing of Ground Granulated Blast Furnace Slag (GGBS) for concrete and cement applications — verifying Blaine fineness, glass content, activity index, soundness and chemical composition.

IS 16714
Standard
±2%
Accuracy
35 Days
Report TAT
NABL
Accredited
NABL Accredited Lab · ISO/IEC 17025:2017
Digital Reports via Autovity QLMS
Pan-India · 7 Lab Locations
Est. 2009 · 20,000+ Projects

What is the GGBS Testing?

Ground Granulated Blast Furnace Slag (GGBS) is a by-product of iron manufacture — quenched molten blast furnace slag ground to cement fineness. GGBS has latent hydraulic properties activated by Portland cement alkalis. Used at 30–70% cement replacement, GGBS reduces heat of hydration, improves long-term strength and dramatically reduces chloride permeability.

At Global Lab, GGBS testing is conducted as per IS 16714 and BS EN 15167 covering Blaine fineness (≥400 m²/kg), glass content (≥85%), activity index at 7 and 28 days, soundness (autoclave expansion), moisture and chemical analysis (CaO, SiO₂, Al₂O₃, MgO, S, Cl) — standard grade GGBS vs Ultrafine GGBS (UGGBS ≥600 m²/kg).

IS 16714 Complete Suite
All mandatory physical and chemical tests per IS 16714 for standard GGBS.
Activity Index at 7 & 28 Days
Hydraulic reactivity confirmed by mortar strength index testing.
Blaine Fineness ≥400 m²/kg
Standard GGBS fineness verified — distinguishes from UGGBS (≥600).
Glass Content ≥85%
Amorphous glass content per XRD or selective dissolution method.
NABL Certified Reports
All results on NABL-accredited letterhead per IS 16714 / BS EN 15167.
Chemical Analysis
CaO, SiO₂, Al₂O₃, MgO, S, Cl, TiO₂ by XRF analysis.

How the GGBS Testing is Conducted

  • 1
    Sample Collection
    GGBS sample from bulk tanker, silo or bag per IS 16714 procedure.
  • 2
    Physical Tests
    Blaine fineness, specific gravity, moisture content and soundness tested.
  • 3
    Activity Index
    Mortar cubes with 50% GGBS + 50% OPC vs 100% OPC control at 7 and 28 days.
  • 4
    Glass Content
    XRD or selective dissolution method to determine amorphous content.
  • 5
    Chemical Analysis & Report
    XRF chemical analysis. IS 16714 compliance checked. NABL report within 35 days.

Applicable Test Standards

Standard Title Scope Type
IS 16714 Ground Granulated Blast Furnace Slag for use in Concrete, Mortar and Grout — Specification GGBS Standard Indian Standard
BS EN 15167 Ground Granulated Blast Furnace Slag for Use in Concrete, Mortar and Grout GGBS Standard British Standard
ASTM C989 Standard Specification for Slag Cement for Use in Concrete and Mortars GGBS ASTM
IS 1727 Methods of Test for Pozzolanic Materials Pozzolan Testing Indian Standard

Where is the CAPO Test Used?

Standard GGBS quality control for ready mix concrete plant use
Mass concrete heat of hydration reduction — dam, raft and mat foundations
Marine concrete chloride resistance improvement with GGBS replacement
GGBS batch acceptance testing for large infrastructure projects
Source approval of GGBS from new steel plant sources
White concrete with GGBS for architectural applications

Our Advantages

NABL Accredited ReportsLegally valid IS 16714 compliance certificates for all project requirements.
Standard vs Ultrafine GGBSBoth standard GGBS (≥400) and UGGBS (≥600 m²/kg) testing available.
Mix Design IntegrationGGBS data directly used in our HPC and mass concrete mix design service.
Autovity Digital ReportsAccess all GGBS test data digitally from any device.
Pan-India CoverageTesting at all 7 NABL-accredited lab locations.
Combined SCM PackageGGBS + UGGBS + Fly ash + Silica fume testing as a complete SCM evaluation.
Get Started Today
Ready to request the GGBS Testing?
Schedule a site visit or send samples — our team responds within 2 hours.