Skip links
Normal Concrete Mix Design — Global Lab India
NABL Accredited · Concrete Service

Normal Concrete Mix Design
(IS 10262 Mix Design)

Scientifically proportioned concrete mix design as per IS 10262 to achieve specified strength, durability and workability — delivering optimised, cost-effective mix proportions for your project grade requirements.

IS 10262
Standard
±5%
Accuracy
7 Days
Report TAT
NABL
Accredited
NABL Accredited Lab · ISO/IEC 17025:2017
Digital Reports via Autovity QLMS
Pan-India · 7 Lab Locations
Est. 2009 · 20,000+ Projects

What is the Normal Concrete Mix Design?

Normal Concrete Mix Design is the systematic process of selecting and proportioning constituent materials (cement, aggregates, water and admixtures) to produce concrete that meets specified requirements of strength, workability, durability and economy. A well-designed mix reduces cement content, controls shrinkage and ensures long-term structural performance.

At Global Lab, mix designs are conducted as per IS 10262:2019 (Guidelines for Concrete Mix Design Proportioning) for grades M10 through M60. Our designs are trial-tested in our NABL-accredited laboratory with fresh property testing (slump, flow, air content) and hardened property testing (7-day and 28-day cube strength).

IS 10262:2019 Compliant
Mix proportions derived as per latest Indian Standard guidelines for all grades.
Actual Site Materials
Mix designed using actual site aggregates, cement and water — not generic values.
Trial Mix Verification
Full trial mix with fresh and hardened concrete testing before final proportions issued.
Cost Optimisation
Minimises cement content while meeting strength and durability requirements.
NABL Certified Mix Design
Mix design report issued on NABL-accredited letterhead with all test data.
All Grades Covered
Normal grades M10 to M60 including PQC, DLC and mass concrete mixes.

How the Normal Concrete Mix Design is Conducted

  • 1
    Material Testing
    All constituent materials — cement (physical & chemical), fine aggregate, coarse aggregate and water — are tested as per relevant IS codes.
  • 2
    Target Strength Calculation
    Target mean strength is calculated from specified characteristic strength and standard deviation as per IS 10262:2019.
  • 3
    W/C Ratio & Aggregate Proportioning
    Water-cement ratio, water content, aggregate proportions and admixture dosage are calculated using IS 10262 method.
  • 4
    Trial Mix Preparation & Testing
    Trial mix is prepared in laboratory. Fresh concrete tests (slump, flow, air content, density) and cube casting are done at 7 and 28 days.
  • 5
    Final Mix Report Issuance
    If trial mix meets target strength and workability, final NABL mix design report with full material data and proportions is issued.

Applicable Test Standards

Standard Title Scope Type
IS 10262:2019 Guidelines for Concrete Mix Design Proportioning Mix Design Indian Standard
IS 456:2000 Plain and Reinforced Concrete — Code of Practice Structural Concrete Indian Standard
ASTM C192 Standard Practice for Making and Curing Concrete Test Specimens Trial Mix ASTM
IS 516 Methods of Tests for Strength of Concrete Cube Strength Indian Standard

Where is the CAPO Test Used?

Residential and commercial building construction — M20 to M40 grades
Infrastructure projects — bridges, flyovers, highways (M40 to M60)
Industrial floors, warehouses and pavements requiring high wear resistance
Mass concrete foundations and raft slabs requiring controlled heat of hydration
Marine and coastal construction requiring high durability and low permeability
Precast concrete elements requiring consistent batch-to-batch quality

Our Advantages

NABL Accredited ReportsMix design reports legally valid and accepted by all structural consultants and authorities.
Actual Site Material TestingMix designed on your actual project materials — not generic industry values.
Full Trial VerificationEvery mix design is trial-tested with 7-day and 28-day cube results before issue.
Autovity Digital PlatformAccess mix design reports and test data from any device 24/7.
Experienced Mix Design Engineers15+ years of mix design experience across all grades and construction types.
Fast TurnaroundPreliminary proportions in 5 days; complete NABL report with 28-day results in 35 days.
Get Started Today
Ready to request the Normal Concrete Mix Design?
Schedule a site visit or send samples — our team responds within 2 hours.