Skip links

Pile Testing

PILE DYNAMIC TESTING

  1. PILE DYNAMIC TEST: Global Lab offers the Pile Dynamic Test of Concrete, steel Piles by complying the requirement of ASTM D 4945: 2012.
  2. OBJECTIVE OF TEST: Dynamic Load Testing is a fast, reliable, and cost-effective method of evaluating foundations. This Test gives more information in less time as follows.
  3. Pile Load Bearing Capacity / Shaft resistance / Shaft resistance along with the shaft / Toe Resistances /  Max Tensile Stresses & Compressive Stresses / Tensile Stresses & Compressive Stresses along with the shaft. 

WHAT TO REPORT THE TEST RESULTS?

  1. Pile shaft Capacity from force and velocity record
  2. Pile Toe resistance, Shaft Resistance & distribution of shaft resistance along the pile shaft.
  3. Pile Net Settlement & Max Displacement during impact.
    Max Compressive stress & Compressive stresses along the shaft length during Impact.
  4. Max Tensile stress & Tensile stresses along the shaft length during Impact.
    Pile Integrity Status.

Pile Integrity Test

Pile Integrity Test Global Lab offers Pile Integrity Testing services to assess the integrity and continuity of concrete piles. This non-destructive test is carried out under the scope of NABL, ensuring reliable and accurate results. With our state-of-the-art equipment and experienced technicians, we can detect defects such as cracks, voids, and soil inclusions that may affect the load- carrying capacity of the pile. Trust us to help you ensure the safety and quality of your construction projects.

Pile Integrity Test

Pile integrity tests (PIT) are non-destructive methods used to evaluate the quality of deep foundation piles. By striking the pile head and measuring the response with sensors, potential defects or damage can be detected. PIT provides cost-effective and reliable results, aiding in the identification of anomalies and ensuring the structural stability of pile foundations. Expert interpretation is crucial for accurate assessment and informed decision-making in construction and maintenance projects.

Pile Pull Out Test

Experience the precision and reliability of Global Lab's Pile Pullout Test services. Our expert team conducts rigorous testing of Concrete Piles, adhering to the standards set by IS 2911 Part-4:2013. With a commitment to accuracy, we provide comprehensive results that ensure the integrity and performance of your pile foundations. 

Pile Pull Out Test

At Global Lab, our objective is to provide you with precise and reliable data through our Pile Pullout Test. This test aims to determine the relationship between the uplift load applied to the pile and the resulting displacement.
When it comes to establishing a safe load for your project, we adhere to the following criteria:
The safe load is taken as the lesser value of the two options below:
Two-thirds (2/3) of the load at which the total displacement reaches 12 mm, or the load corresponding to a specified permissible uplift.
Half of the load at which the load-displacement curve exhibits a clear break, indicating a downward trend.

Pile Testing

Static Pile Load Test

Global Lab is your trusted provider of Pile Static Load Testing services, offering capabilities of up to 2000T in accordance with IS 2911 Part-4.
Our testing facility operates under the scope of NABL, ensuring the highest standards of quality and reliability.

Pile Static Load Test

Load Testing services for accurate validation of pile designs, assessment of load-bearing capacity, and assurance of structural safety. With our state-of-the-art facilities and adherence to relevant standards, we provide reliable and comprehensive test results.

Get a Free Quote

    Call us at

    98200 04115

    Pile Vertical Cyclic Load Test

    Global Lab offers Pile Vertical Cyclic Load Testing services as per IS 2911 Part-4 evaluate separately skin friction and point bearing load on single Pile of uniform diameter. These tests are conducted in accordance with industry standards and can be performed on a variety of pile types and sizes. Our experienced team uses state-of-the-art equipment to measure deflection of pile during Loading & unloading and the resulting data is analysed to determine pile properties

    EVALUATION OF TEST OBSERVATION:

    Pile Dia Up to and including 600mm: The safe vertical load on the single pile shall be the least of the following:

    • Two-thirds of the load at which the total displacement is 12 mm or the load corresponding to a specified permissible displacement; and  
    • Half of the load at which the displacement attained 10% of the pile dia. 
      Pile Dia more than 600mm:
       The safe vertical load on the single pile shall be the least of the following:
    • Two-thirds of the load at which the total displacement is 18 mm or a maximum of 2 percent of pile diameter whichever is less or the load corresponding to a specified permissible displacement; and 
    • Half of the load at which the displacement attained 10% of the pile dia. 

    PILE LATERAL LOAD TEST

    Global Lab offers the Pile Lateral Load Test of Concrete, steel Piles by complying the requirement of IS 2911 PART-04: 2013.

     

    PILE LATERAL LOAD TEST:

    OBJECTIVE OF TEST: To measure the lateral deflection of a vertical or inclined deep foundation when subjected to lateral loading.